TRANSCOAT is a water based, water insulation and prime coat material that provides perfect water repellence by impregnating the application surface and creating an invisible barrier against water in the capillary channels.
Preparation of Substrate
Damaged joints must be repaired and filled. The application surfaces must be clean, dry and clean off oil, rust, dirt, mildew, etc. The cracks, loose parts on the surface must be repaired.
Application Method
TRANSCOAT is ready to use material, it should be mixed thoroughly before application. It should be applied with brush or rake at least two layers. It must be applied with saturation technique, coat after coat, without waiting for the former coat to dry up. Recommended that waiting 24 hours before any topcoat application. Before the application into joints of non-porous surfaces such as ceramic, faience etc. the joints must be repaired and filled. After the application, any material smeared onto bright surface must be wiped off with a damp cloth. TRANSCOAT is not suitable on painted surface, under pressure water or in underground conditions with high hydrostatic pressure.
0,150 – 0,350 kg/m2 for each layer depending on absorbency of the surface. Recommended at least 2 layers application.
1 kg plastic bucket/4,5 kg plastic bucket/20 kg drum